Stainless, Galvanizing & Corrosion

Fire Protection of Structural Steel: Options and Specification

How structural steel is protected from fire: why steel loses strength, fire resistance ratings, intumescent coatings, boards, sprays, concrete encasement and Saudi Civil Defense requirements.

Saudi Steel Work Editorial Team · · 3 min read

Short answer: Structural steel loses strength as it heats, so fire codes require protection to achieve fire resistance ratings such as 60, 90 or 120 minutes. Common methods are intumescent coatings, sprayed cementitious or mineral fibre coatings, fire boards and concrete encasement. The required rating comes from the building code, and protection thickness depends on section size and design temperature.

Steel doesn't burn, but it softens in fire. Fire protection buys time for evacuation and firefighting and prevents premature collapse.

Why protection is needed

As steel temperature rises, its yield strength and stiffness fall. Design temperatures depend on load ratio and code approach, often in the 500–600 °C range. Unprotected light sections can reach these temperatures quickly in a fully developed fire.

Fire resistance requirements

The Saudi Building Code (including SBC 201 and SBC 801) and Civil Defense requirements set required fire resistance by building type, height and occupancy. Ratings are expressed in minutes (e.g. R60, R90, R120).

Section factor

The section factor (Hp/A) measures how quickly a section heats. Lighter sections and hollow sections with thin walls need more protection; heavy sections need less.

Protection methods

Method Advantages Considerations
Intumescent coating Thin, decorative, shows steel form; shop or site applied Higher cost for long ratings; needs suitable topcoat externally
Sprayed cementitious / mineral fibre Economical for long ratings Bulky, not decorative; used in hidden areas
Fire boards Clean, predictable thickness; dry installation Labour-intensive; joints and fixings
Concrete encasement Robust, long ratings Heavy, slow
Concrete-filled hollow sections Inherent fire resistance Design-dependent

Specifying intumescent coatings

  • Product must be tested and assessed for the section types and ratings required
  • Thickness determined from manufacturer's tables by section factor and critical temperature
  • Compatible primer and topcoat
  • DFT measured and recorded

Interaction with corrosion protection

Fire coatings must be compatible with the anti-corrosion primer. Coordinate both specifications early (paint systems for structural steel).

Composite floors

Composite slabs on steel decking achieve fire resistance through slab depth and reinforcement, often reducing protection needed on beams (composite decking).

See structural steel fabrication for shop-applied coatings.

Frequently asked questions

At what temperature does steel lose strength?
Steel progressively loses strength as it heats; around 550 °C it retains roughly half its room-temperature strength, which is why that temperature is often referenced in fire design.
What is section factor?
The ratio of heated perimeter to cross-sectional area (Hp/A). Thin, light sections heat faster and need thicker protection than heavy sections.

Keep reading

Rebar & Construction Steel

ASTM A615 Grade 60 Rebar Explained

ASTM A615 Grade 60 reinforcing bar explained: 420 MPa yield, deformation pattern, bend test, markings, A615 vs A706, and use with SASO requirements in Saudi Arabia.

6 November 2026 · 3 min read

Saudi Steel Market

Green Steel and Low-Carbon Construction in Saudi Arabia

What green or low-carbon steel means, how DRI-EAF and hydrogen reduce emissions, EPDs, Saudi Green Initiative, Mostadam ratings and how buyers can specify lower-carbon steel.

6 November 2026 · 3 min read

Saudi Steel Market

Hydrogen DRI Steelmaking Explained

How direct reduced iron (DRI) works with natural gas and hydrogen, why it matters for low-carbon steel, the role of electric arc furnaces, and the relevance for Saudi Arabia.

6 November 2026 · 3 min read

Request a quotation

Send us your steel schedule

Share drawings, a BOQ or a simple list. We will confirm availability, lead time and documentation before you commit.